MRCOOL VersaPro 2nd Gen Central Split System with 36K BTU, 3 Ton, 16.1 SEER2, Heat Pump Condenser and Ducted Air Handler with 15 Ft. R-454B No-Vac Lineset - MVP-36-HP-230A15-Schneller Versand
SALE!

MRCOOL VersaPro 2nd Gen Central Split System with 36K BTU, 3 Ton, 16.1 SEER2, Heat Pump Condenser and Ducted Air Handler with 15 Ft. R-454B No-Vac Lineset – MVP-36-HP-230A15-Schneller Versand

Original price was: CHF2'907.00.Current price is: CHF298.98.

SKU: 8375534223551 Category:

Description

MRCOOL VersaPro 2nd Gen Central Split System with 36K BTU, 3 Ton, 16.1 SEER2, Heat Pump Condenser and Ducted Air Handler with 15 Ft. R-454B No-Vac Lineset – MVP-36-HP-230A15

The MRCOOL Central Split System Bundle is a heating and cooling system you need to stay warm in winter, cool in summer, and energy efficient all year long.

Features
  1. MRCOOL VersaPro 2nd Gen 36K BTU, 3 Ton, 16.1 SEER2 Central Ducted Heat Pump Condenser

  2. MRCOOL VersaPro 2nd Gen 36K BTU, 3 Ton Central Ducted Air Handler

  3. MRCOOL 15 Ft. R-454B No-Vac Lineset

  4. MRCOOL Smart Thermostat

  5. 1. MRCOOL VersaPro 2nd Gen 36K BTU, 3 Ton, 16.1 SEER2 Central Ducted Heat Pump Condenser (MVP-36-HP-C-230A00-O)

  • 3 Ton

  • 16.1 and an HSPF4 rating of 8.7.

  • R-454B refrigerant

2. MRCOOL VersaPro 2nd Gen 36K BTU, 3 Ton Central Ducted Air Handler (MVP-36-HP-MUAH-230A00-O)

  • 3 Ton

  • SEER2 rating of up to 17.4

  • R-454B refrigerant

3. MRCOOL 15 Ft. R-454B No-Vac Lineset (NV15-3834-O)

  • Kink Resistant – Precharged

  • Simple Secure Quick Connect

  • UV Protected Insulation

  • Works With: VersaPro 2nd Gen – Central Ducted Hyper Heat 2nd Gen

4. MRCOOL Smart Thermostat (MST04)

  • Ensure ideal temperature with presets for Home, Away, and Sleep that perfectly align to match your specific needs and preferences.

  • One App for All Your HVAC Systems

  • Global Control for Remote Accessibility

  • Works with Alexa, Google, Siri, and MRCOOL® Link

Specifications
Condenser
Dimensions 16.14″ D x 31.89″ H x 37.24″ W
SEER2 16.1
Tonnage 3
Cooling Capacity (BTU) 36000
Heating Capacity (BTU) 36000
Voltage (V) 208-230
Refrigerant Type R454B
Air Handler
Dimensions 21.02″ D x 49.02″ H x 21.02″ W
Tonnage 3
Cooling Capacity (BTU) 36000
Heating Capacity (BTU) 36000
Voltage (V) 115/208-230
Lineset
Dimensions 30″ D x 30″ H x 5″ W
Refrigerant Type R-454B
Refrigerant Volume (Oz) 2.11
Line Set Length 15ft
Lineset Fitting Type Quick-Connect
Liquid Line Size 3/8
Suction Line Size 3/4
What our Experts Think
  • Reliable Year-Round Comfort – 36,000 BTU (3 Ton) system efficiently heats and cools medium-to-large homes.

  • Energy-Efficient Performance – 16.1 SEER2 rating delivers lower energy costs while maintaining comfort.

  • Heat Pump Technology – Provides consistent heating and cooling throughout the year.

  • 15 Ft. R-454B No-Vac Lineset – Pre-charged line set simplifies installation and reduces labor time.

  • Durable & Quiet – 2nd Gen design ensures long-lasting, low-noise operation.

Q&A

Q: What is included in this MRCOOL VersaPro 2nd Gen system?
A: It includes a 36,000 BTU (3 ton) heat pump condenser, ducted air handler, and a 15 ft. pre-charged R-454B No-Vac lineset for simplified installation.

Q: How energy efficient is the system?
A: With a 16.1 SEER2 rating, it delivers efficient cooling and heating while reducing energy consumption.

Q: Can it provide both heating and cooling?
A: Yes, the heat pump condenser ensures year-round comfort with both heating and cooling capabilities.

Q: What makes the No-Vac lineset beneficial?
A: The pre-charged R-454B No-Vac lineset eliminates the need for vacuum pumps or additional refrigerant charging, simplifying installation.

Q: What size area can it cover?
A: Suitable for medium-sized homes up to approximately 1,500–2,000 sq. ft., depending on insulation and climate.

Q: Who should choose this system?
A: Homeowners looking for a mid-size, energy-efficient central HVAC system with easy installation and reliable year-round performance.

Maintenance Tips
  • Air Filter Care: Replace or clean filters every 1–3 months to maintain airflow and efficiency.

  • Outdoor Unit Maintenance: Keep condenser free of debris, leaves, and obstructions.

  • Ductwork Inspection: Seal leaks and clean ducts regularly for consistent air distribution.

  • Condensate Drain: Ensure drain lines are clear to prevent water buildup.

  • Coil Cleaning: Schedule annual cleaning of evaporator and condenser coils to maintain peak performance.

  • Lineset Check: Inspect the 15 ft. R-454B No-Vac lineset for proper installation and insulation.

  • Professional Service: Schedule yearly maintenance to maximize SEER2 efficiency and prolong system life.

Reviews

There are no reviews yet.

Be the first to review “MRCOOL VersaPro 2nd Gen Central Split System with 36K BTU, 3 Ton, 16.1 SEER2, Heat Pump Condenser and Ducted Air Handler with 15 Ft. R-454B No-Vac Lineset – MVP-36-HP-230A15-Schneller Versand”

Deine E-Mail-Adresse wird nicht veröffentlicht. Erforderliche Felder sind mit * markiert